NEW QUESTION 203
UPS2000-G-(6K- 20K) has a strong lightning protection design in the industry, lightning protection level (), surge protection level (), can avoid 90 failures caused by lightning strikes, and reliably protect the exchange of back-end equipment. input port.
- A. 2kA; 4kV
- B. 5kA; 6kV
- C. 2kA; 6kV
- D. 4kA; 6kV
Answer: B
NEW QUESTION 204
Huawei air-cooled air conditioners (25kw and 42kw) one indoor unit corresponds to one outdoor unit
- A. True
- B. False
Answer: A
NEW QUESTION 205
NetCo15000-C row-level chilled water intelligent cooling product supports return air, supply air, cold aisle, hot aisle and other types of temperature and humidity control ( )
- A. True
- B. False
Answer: A
NEW QUESTION 206
Regarding the FusionModule2000 wiring, which of the following statements is wrong?
- A. The power distribution cabinet/integrated UPS can not be placed at the head of the column
- B. Cross-channel routing through the control skylight
- C. The power distribution cabinet/integrated UPS can be placed outside the module
- D. There are two wiring slots at the top of the cabinet, with a total of 4 slots for 2 channels of strong current, one channel of weak current, and one channel of optical fiber.
- E. Cross-channel routing can be configured with cable ladders to route cables across the top of the fixed skylight
Answer: C
NEW QUESTION 207
The output power factor of UPS2000-G-(6K-20K) is ( ), which is suitable for new IT loads and significantly improves the load capacity of the system.
- A. 0.9
- B. 0.7
- C. 0.8
- D. 0.99
Answer: A
NEW QUESTION 208
FusionModule1000A V2R3 version prefabricated integrated data center has Najishen solution (multiple choice)
- A. 40 feet ICT solution
- B. 40-foot CT Solution
- C. 20-foot CT Solution
- D. 40 feet IT solution
- E. 20 feet IT solution
Answer: A,C,D
NEW QUESTION 209
What are the dimensions of Huawei cabinets? ()Multiple choice.
- A. 600* 1200* 2200
- B. 800*1200*2200
- C. 600* 1200* 2000
- D. 800*1200* 2000
Answer: A,B,C,D
NEW QUESTION 210
Which of the following statements are true about the iBattery battery management system? ()
- A. iBattery can be connected to UPS
- B. iBOX can be powered by DC 48V or POE
- C. The iBat signal is wirelessly connected to the iBOX
- D. iBattery can manage battery
Answer: A,B,C,D
NEW QUESTION 211
The asset management in the NetEco management system can manage the asset information of which of the following devices to realize the life cycle management of assets? (multiple choice)
- A. Air conditioning
- B. Power distribution cabinet
- C. UPS
- D. server
Answer: A,B,C,D
NEW QUESTION 212
Among the following options, which statement is correct regarding the reliability of UPS5000-A (30kVA~120kVA)
- A. Three anti-paint coating technology
- B. Ultra-wide input voltage range
- C. Inverter overload capacity is strong
- D. 6kV/5kA lightning protection design
Answer: A,B,C,D
NEW QUESTION 213
A project requires the management system to be connected to a third-party generator set, two smart meters (same model), and two precision air conditioners (same model), then the management system needs to report ( ) a third-party equipment access fee?
- A. 0
- B. None of the above is true.
- C. 1
- D. 2
Answer: C
NEW QUESTION 214
Huawei's prefabricated power modules contain the following configurations ( ).
- A. Transformer
- B. Compensation Cabinet
- C. Feeder cabinet
- D. UPS
Answer: A,B,C,D
NEW QUESTION 215
Compared with the chilled water scheme, which of the following is not an advantage of AHU ( )
- A. Less difficult operation and maintenance
- B. Easier deployment
- C. Wider range of applications
- D. Lower PUE
Answer: C
NEW QUESTION 216
When the distance between the outdoor unit and the seaside is 0.5km~3.7km, you need to configure the () outdoor unit
- A. class b
- B. Class d
- C. class c
- D. Class a
Answer: C
NEW QUESTION 217
UPS5000-E (25-125kVA) does not support iBattery function.
- A. True
- B. False
Answer: B
NEW QUESTION 218
What kind of access control can the rear door of the FusionModule2000 cabinet support? A Mechanical code lock B IC card swipe access control C Three-in-one access control D None of the above Answers: D 216.
The NetEco6000 management system can provide energy efficiency management functions. Which of the following functions are supported? (multiple choice)
- A. The electricity consumption report of each cabinet can be generated, which is convenient for customers to count the electricity consumption of each department.
- B. You can understand the energy expenditure cost of the computer room according to the electricity cost of the computer room with the stepped electricity price
- C. The PUE of the computer room can be monitored to understand the current energy efficiency level
- D. The pPUE of each micro-module can be monitored to understand the energy efficiency level of each micro-module
Answer: A,B,C,D
NEW QUESTION 219
The controller (ECC800) of Fusionmodule2000 can be linked with the building fire protection system ( )
- A. True
- B. False
Answer: A
NEW QUESTION 220
The number of standard battery cells of a single battery pack of UPS2000-G (6-20K) is ()
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION 221
UPS2000-G-(6K-10K) battery voltage is 240V, 15K/20K battery voltage is 480V.
- A. True
- B. False
Answer: A
NEW QUESTION 222
The single cooling capacity range of the water-cooled centrifugal unit is:
- A. 100-1000kW
- B. 500-5000kW
- C. 300-3000kW
- D. 200-2000kW
Answer: C
NEW QUESTION 223
Which of the following functions or components does the UPS5000-E (50kVA power module) come standard with? ( )
- A. Parallel function
- B. SNMP function
- C. Dry contact communication card
- D. Bus synchronization control function
Answer: A,B,C,D
NEW QUESTION 224
......